Skip to content
Guides and contractor referrals for Des Moines, WA and the South Sound shore
Rules guide

Des Moines Crawl Space Rules and Permits, WA

Washington crawl space rules come mainly from one section of the state residential code, WAC 51-51-0408: a six-mil black polyethylene ground cover, 1 square foot of vent per 300 square feet of floor, and a numbered list of items for a crawl space with no vents.

This guide explains the rules a Des Moines homeowner is most likely to meet at the City's Permit Center, in plain words, with links to the official text. The company's Washington crawl space code guide reads the state text section by section. It is general information, not legal advice. Your city's building department has the final word on your project.

Where Washington crawl space rules come from

Washington adopts the International Residential Code with its own amendments, published as chapter 51-51 of the Washington Administrative Code. The crawl space rules sit in one amended section, WAC 51-51-0408, "Under-floor space". It was last amended by WSR 23-23-104, effective March 16, 2024.

Energy rules, including floor insulation, are in a separate code, the Washington State Energy Code for residential buildings (chapter 51-11R WAC). Both are set by the State Building Code Council. Washington's next code cycle has been delayed, so check the State Building Code Council for the edition in force when your permit is issued.

TopicWhere the rule lives
Ground cover, vents, unvented crawl spacesWAC 51-51-0408
Floor insulation level and installationWAC 51-11R, Table R402.1.3 and section R402.2.7
Contractor registration and advertisingRCW 18.27
Seller disclosureRCW 64.06.020
Steep slopes and ravines in Des MoinesDes Moines Municipal Code 16.10

The ground cover rule

Section R408.1 requires a ground cover of six-mil (0.006-inch-thick) black polyethylene or an approved equal over the soil in a crawl space. The joints must overlap by 6 inches and the cover must reach the foundation wall. It can be left out only where the crawl space has a concrete slab at least 2 inches thick.

Two words in that rule matter. "Black" rules out the clear plastic often thrown down in a hurry. And "approved equal" leaves room for heavier materials, which is what most encapsulation liners are. Our vapor barrier installation page shows how a code-compliant cover goes in.

Vent area and vent coverings

Section R408.2 sets the size of the vents in a vented crawl space. Washington requires at least 1 square foot of net vent area for every 300 square feet of under-floor area, placed for cross ventilation. One side of the building may have no openings. The national model code uses 1 per 150, so Washington allows about half the vent area of the printed IRC.

The vents must be covered with an approved material: perforated or expanded sheet metal, cast-iron grills, extruded brick vents, hardware cloth or corrosion-resistant mesh. The smallest dimension of the covering's openings can't exceed ¼ inch. Operable louvers are allowed.

Crawl space floor areaMinimum net vent area at 1/300
600 sq ft2 sq ft
900 sq ft3 sq ft
1,200 sq ft4 sq ft
1,500 sq ft5 sq ft

Net vent area is the open area after the screen, not the size of the hole in the wall, so a screened vent counts for less than its frame.

Reducing the vents with a Class I vapor retarder

An exception in R408.2 lets the vent area drop to 1 square foot per 1,500 square feet of floor when the ground is covered with a Class I vapor retarder and cross ventilation is still provided. That is how many Washington crawl spaces get most of the benefit of sealing while keeping some airflow.

There is a condition. If the vent area falls below 1 per 300, or operable louvers are installed, the code requires a radon vent built to its Appendix AF. Less outside air means soil gas has fewer ways out, so the code gives it a pipe. Our post on whether crawl space vents should be open or closed in winter looks at the everyday side of this.

Crawl spaces with no vents at all

Section R408.3 lists what a crawl space with no vent openings must have, and the building official decides how it applies to a given house:

  1. The exposed earth is covered (R408.3) with a continuous Class I vapor retarder, overlapped 6 inches, sealed or taped, and run at least 6 inches up the stem wall, and a radon system meeting Appendix AF is installed.
  2. Continuous mechanical exhaust ventilation is provided at 1 cubic foot per minute for each 50 square feet of crawl space floor, discharged outside.

Washington lists no dehumidifier or conditioned-air option in place of the exhaust, and the City's building official confirms how the two items apply to a given design. There is a narrow exception for existing buildings that use the crawl space as a heating plenum. Washington also lists the model code's section R408.8 on under-floor vapor retarders as "not adopted".

DesignVentsGround coverExtra requirements
Standard vented1 sq ft per 300 sq ftSix-mil black polyNone
Reduced ventsDown to 1 per 1,500Class I vapor retarderRadon vent if below 1/300 or louvered
UnventedNoneClass I retarder, sealed 6 in. up the stem wallAppendix AF radon system and continuous exhaust at 1 cfm per 50 sq ft

This is why "seal the vents and add a dehumidifier" is an incomplete description of a Washington encapsulation. The crawl space encapsulation page walks through both paths.

What the energy code says about floor insulation

For floors over a crawl space, the Washington State Energy Code calls for R-30 insulation in the state's climate zones (Table R402.1.3). Section R402.2.7 adds how it must be installed: in permanent contact with the underside of the subfloor, or filling the framing cavity from top to bottom. Where the top of a foundation vent isn't below the insulation, a baffle is required.

In practice, insulation that sags away from the floor doesn't meet the installation rule, even if the batts are thick enough. Our crawl space insulation page covers how new insulation is held in place.

Radon and Washington crawl spaces

Radon is a radioactive gas from the soil. The EPA calls it the second leading cause of lung cancer overall and the leading cause among people who have never smoked, and recommends fixing a home at 4 pCi/L or higher.

King County sits in the EPA's lowest radon zone, with a predicted average below 2 pCi/L, but the EPA map for Washington says all homes should be tested regardless of zone. The Washington State Department of Health calls testing best practice and the first step. The building code ties radon to crawl space design: reduced vents or no vents bring in an Appendix AF radon vent or system. Read more in our post on crawl spaces and radon in King County homes.

Contractor registration and what advertising must show

Washington requires construction contractors to register with the Department of Labor & Industries. Under RCW 18.27.100, advertising that shows a contractor's name or address must show the contractor's current registration number. The same statute bars contractors from advertising that they are "bonded and insured" on the strength of the bond the law requires.

L&I registers contractors by specialty. Under WAC 296-200A-016, the "Insulation and acoustical" specialty covers installing, altering and repairing insulation, and the concrete specialty includes placing film barriers, sealing and waterproofing. There is no separate "crawl space" specialty.

L&I Verify shows any contractor's registration status and specialty, and RCW 18.27.100 puts the registration number on its advertising.

A few questions separate a careful bid from a loose one:

  1. What is your L&I registration number? Then look it up yourself.
  2. Which code path is this design? A vented space with a new ground cover, a reduced-vent design with a Class I retarder, or an unvented space under R408.3. Each carries different requirements, and the Des Moines building official confirms how they apply to your address.
  3. What did you find, and do the photos show it? A careful bidder can show the problem it is pricing.
  4. Where does the water come from, and where will it go? A sump that discharges onto a neighbor's slope is a new problem.
  5. What about radon? Reduced-vent and unvented designs bring in the Appendix AF radon provision.
  6. What will I get at the end? A photo report lets you, a buyer or an inspector see the work.

Be wary of a pitch that promises big heating savings in this climate. A U.S. Department of Energy Building America research profile found that in the Pacific Northwest marine climate, vented and closed crawl spaces both performed adequately as long as the ducts were not in the crawl space.

Permits by city

Whether crawl space work needs a permit depends on what is done and where. A barrier swap is usually treated differently from new plumbing, wiring or drainage. The contractors we pass Des Moines requests to work inside the City of Des Moines, so its Permit Center is the desk that matters here. Federal Way is listed only because its line runs close to Woodmont and Redondo, and an address on the far side of it goes to that city's desk.

CityWhat the official source saysWho to ask
Des MoinesIts permit memo lists relocating plumbing and most electrical work as needing permits. It doesn't address insulation, vapor barriers or sump pumpsBuilding Division
Federal Way (neighboring city, not served)Uses the code's exemption list, but any work in a critical area, including landslide hazard areas and their buffers, is not exemptFederal Way permit center

When a sump pump adds a new circuit or a discharge line, the electrical and plumbing rules can apply even where the crawl space work itself doesn't need a permit, so confirm with the permit center for the address before work starts.

Steep slopes, ravines and bluffs

Des Moines regulates work near its ravines and bluffs through its critical areas code, DMMC 16.10. It applies to development proposals that need a building, grading or right-of-way permit. Ravine sidewalls and bluffs carry a 50-foot native-vegetation buffer, which a geotechnical engineer's statement can reduce to 10 feet, and erosion and landslide hazard areas carry a buffer equal to the slope height or 50 feet, whichever is greater.

Federal Way's geologically hazardous areas bulletin sets a standard 50-foot buffer plus a 5-foot structural setback from the top and toe of a landslide hazard slope. Crawl space work usually stays inside the house's footprint, but digging for drainage or discharge lines outside it on these lots can bring the critical areas rules into play. On a Redondo Beach Drive lot the seawall and bluff sit close together; the post on whether water under a Redondo Beach Drive home comes from the Sound or the bluff walks through that case.

What Washington sellers must disclose

Washington's seller disclosure statement, set out in RCW 64.06.020, doesn't mention crawl spaces by name, but several of its questions reach under the floor.

Form questionWhy it matters for a crawl space
Has the basement flooded or leaked?Some buyers and agents read crawl space water into it
Any settling, slippage or sliding of the property?Relevant on sloped lots
Any wood destroying organism or pest infestation?Rodent and insect damage under the floor
Any flooding, standing water or drainage problems on the property?The most direct crawl space question
Radon gasListed among environmental conditions

A documented repair with photos is the easiest way to answer these honestly. A seller does best to fix the cause of any water first, then the cover, so the answer on the form is accurate; a sheet of plastic thrown down the week before listing rarely fools an inspector. A buyer can read the inspection report's crawl space section line by line: "limited access", "moisture noted" and "insulation displaced" are worth a second look, and booking a crawl space visit early in the inspection window leaves time for a written scope to take back to the seller. Our post on why older Des Moines, WA homes have damp crawl spaces covers what that moisture usually means.

Vent screens and rodents

The code's ¼-inch limit on vent coverings lines up with public health advice. Public Health – Seattle & King County says rats can get through holes the size of a quarter and mice through holes the size of a dime, and recommends ¼-inch hardware cloth over openings (PHSKC fact sheet). The Washington State Department of Health lists crawl space vents and entry points among the places to inspect.

A torn vent screen is a code issue and a rodent issue at the same time, and it is one of the cheapest repairs in a crawl space.

Vents in a hard freeze

The code sets the permanent vent area, but it doesn't stop you covering vents for a few days in a cold snap. Sea-Tac Airport averages about 25 days a year at or below freezing, according to NOAA's 1991 to 2020 normals, mostly in December and January.

Seattle Public Utilities, which doesn't serve Des Moines but gives sound regional advice, says pipes exposed to drafts from open foundation vents are most at risk of freezing, and suggests closing vents with wood or foam blocks during cold weather (SPU). It also says to open them again in spring to prevent dry rot. A temporary cover keeps the pipes safe, and reopening keeps the crawl space within the rules it was built to.

Where these rules apply in Des Moines

These rules apply across the city's neighborhoods, and a registered contractor should know them before quoting. For prices, see our crawl space repair cost guide, and for the full picture start from our crawl space home page for Des Moines.

Frequently asked questions

How many square feet of vents does a Des Moines rambler need?

Divide the crawl space floor area by 300: a 1,200-square-foot rambler in North Hill needs 4 square feet of net vent opening under WAC 51-51-0408. Lay a Class I vapor retarder and keep cross ventilation, and the divisor becomes 1,500, so the same house needs 0.8 square feet, plus the radon vent the code then asks for.

Is clear plastic allowed as a crawl space ground cover in Washington?

Washington's code names six-mil black polyethylene or an approved equal as the ground cover, so clear plastic doesn't meet the plain wording of the rule. Heavier approved liners do. Ask your building department if you're unsure about a specific product.

Can I seal my crawl space vents myself?

Sealing all the vents makes the crawl space unvented under Washington's code, and R408.3 then lists two numbered items, a sealed Class I retarder with a radon system and continuous exhaust ventilation; the building official confirms how they apply. Closing vents alone answers neither item. Temporary covers in a hard freeze are a different matter, covered in our vent post.

What R-value does Washington require under a floor?

The Washington State Energy Code calls for R-30 floor insulation over crawl spaces in the state's climate zones. It also requires the insulation to stay in contact with the subfloor, or to fill the framing cavity, so the installation matters as much as the thickness.

How do I check a crawl space contractor's registration?

You can check any crawl space contractor's registration on L&I Verify at secure.lni.wa.gov/verify. Search by name or registration number and confirm that the status is active and the specialty fits the work. The number should also appear in the contractor's advertising.

Does a crawl space repair have to be disclosed when I sell?

Washington's seller disclosure form asks about flooding, standing water and drainage problems, pest infestation and radon, so the conditions behind a crawl space repair usually come up. Answer them truthfully, and keep the repair photos and invoice to show what was fixed.

Getting the rules right on your house